GSO IEC 61462:2014

IEC 61462:2007
Gulf Standard   Current Edition · Approved on 25 December 2014

Composite hollow insulators - Pressurized and unpressurized insulators for use in electrical equipment with rated voltage greater than 1 000 V - Definitions, test methods, acceptance criteria and design recommendations

GSO IEC 61462:2014 Files

GSO IEC 61462:2014 Scope

This International Standard applies to composite hollow insulators consisting of a load-bearing insulating tube made of resin impregnated fibres, a housing (outside the insulating tube) made of elastomeric material (for example silicone or ethylene-propylene) and metal fixing devices at the ends of the insulating tube. Composite hollow insulators as defined in this standard are intended for general use (unpressurized) or for use with a permanent gas pressure (pressurized). They are intended for use in both outdoor and indoor electrical equipment operating on alternating current with a rated voltage greater than 1 000 V and a frequency not greater than 100 Hz or for use in direct current equipment with a rated voltage greater than 1 500 V. The object of this standard is: – to define the terms used; – to prescribe test methods; – to prescribe acceptance criteria. This standard does not prescribe impulse voltage or power frequency voltage type tests, nor does it prescribe pollution tests because the withstand voltages are not characteristics of the hollow insulator itself, but of the apparatus of which it ultimately forms a part. All the tests in this standard, apart from the thermal-mechanical test, are performed at normal ambient temperature. This standard does not prescribe tests that may be characteristic of the apparatus of which the hollow insulator ultimately forms a part. Further technical input is required in this area. NOTE 1 "Pressurized" means a permanent gas or liquid pressure greater than 0,05 MPa (0,5 bar) gauge. The gas can be dry air or inert gases, for example sulphur hexafluoride, nitrogen, or a mixture of such gases. NOTE 2 "Unpressurized" means a gas or liquid pressure smaller than or equal to 0,05 MPa (0,5 bar) gauge. NOTE 3 Composite hollow insulators are intended for use in electrical equipment, such as, but not limited to • circuit-breakers, • switch-disconnectors, • disconnectors, • earthing switches, • instrument- and power transformers, • bushings. Additional testing defined by the relevant IEC equipment committee may be required.

Best Sellers From Electrical Sector

GSO 2530:2016
 
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
OS GSO 2530:2016
 
Omani Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
OS GSO 34:2007
 
Omani Standard
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES
GSO 34:2007
 
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES

Recently Published from Electrical Sector

GSO IEC/IEEE 60214-2:2022
IEC/IEEE 60214-2:2019 
Gulf Standard
Tap-changers - Part 2: Application guidelines
GSO IEC 60076-22-2:2022
IEC 60076-22-2:2019 
Gulf Standard
Power transformers - Part 22-2: Power transformer and reactor fittings - Removable radiators
GSO IEC 60076-7:2022
IEC 60076-7:2018 
Gulf Standard
Power transformers - Part 7: Loading guide for mineral-oil-immersed power transformers
GSO IEC 62841-2-4:2022
IEC 62841-2-4:2014 
Gulf Standard
Electric motor-operated hand-held tools, transportable tools and lawn and garden machinery - Safety - Part 2-4: Particular requirements for hand-held sanders and polishers other than disc type