GSO ISO 7027-1:2021

ISO 7027-1:2016
Gulf Standard   Current Edition · Approved on 01 July 2021

Water quality — Determination of turbidity — Part 1: Quantitative methods

GSO ISO 7027-1:2021 Files

GSO ISO 7027-1:2021 Scope

ISO 7027-1:2016 specifies two quantitative methods using optical turbidimeters or nephelometers for the determination of turbidity of water:

a) nephelometry, procedure for measurement of diffuse radiation, applicable to water of low turbidity (for example drinking water);

b) turbidimetry, procedure for measurement of the attenuation of a radiant flux, more applicable to highly turbid waters (for example waste waters or other cloudy waters).

Turbidities measured according to the first method are presented as nephelometric turbidity units (NTU). The results typically range between <0,05 NTU and 400 NTU. Depending on the instrument design, it can also be applicable to waters of higher turbidity. There is numerical equivalence of the units NTU and formazin nephelometric unit (FNU).

Turbidity measured by the second method is expressed in formazin attenuation units (FAU), results typically range between 40 FAU and 4 000 FAU.

Best Sellers From Chemical and Textile Sector

GSO 1943:2021
 
Gulf Technical Regulation
Cosmetic Products – Safety Requirements of Cosmetics and Personal Care Products
OS GSO 575:2016
 
Omani Standard
Facial tissue - paper
GSO 575:2016
 
Gulf Standard
Facial tissue - paper
OS GSO 1948:2009
 
Omani Standard
Germicidal liquid detergent for general purposes

Recently Published from Chemical and Textile Sector

GSO 10302:2024
 
Gulf Standard
TITLE IN ENGLISH
GSO ASTM F2755:2022
ASTM F2755:14 
Gulf Standard
Standard Safety Specification for Cautionary Labeling of Inflatable Air Mattresses
GSO ISO 16178:2022
ISO 16178:2012 
Gulf Standard
Footwear — Critical substances potentially present in footwear and footwear components
GSO ISO 13885-2:2022
ISO 13885-2:2020 
Gulf Standard
Gel permeation chromatography (GPC) — Part 2: N,N-Dimenthylacetamide (DMAC) as eluent